Li-SOCl₂ batteries for smart metering

Long standing time plus periodic transmission pulses: metering devices need a cell chosen against both halves of the load profile.

A meter spends most of its life drawing very little current and then draws a short pulse when it transmits or closes a relay. Both halves of that profile matter: the standing load decides capacity, and the pulse decides whether the cell alone can hold the voltage the meter needs.

Selection therefore starts from the reading and transmission cycle, not from a model number. Send the working current, the peak current during transmission, the pulse duration and frequency, the meter’s cut-off voltage and the temperature range the installation sees.

What decides the battery

Application and device

Sets the operating environment and the design direction

Working current

The average load the cell carries between transmissions

Peak current

What the meter draws when it transmits or switches a relay

Pulse duration

How long each transmission pulse lasts

Pulse frequency

How often the pulse repeats — determines recovery time

Cut-off voltage

The lowest voltage the meter electronics still operate at

Operating temperature

Installation environment, including outdoor cabinets

Which configuration fits

A single ER cell may be sufficient where the transmission pulse is modest. Where the pulse pulls the terminal voltage below the meter's cut-off level, an ER + pulse capacitor configuration lets the capacitor carry the pulse while the cell supplies average energy. Series or parallel packs are used where the meter needs a voltage or capacity a single cell cannot provide.